25
Jan
11

BUILDING ENERGY EFFICIENCY STANDARDS

Title 24, Part 6, of the California Code of Regulations

Effective January 2010, the California Energy Commission promulgated changes to the “2008 Building Energy Efficiency Standards”, for residential and non-residential buildings.

I recommend a visit to their website at www.energy.ca.gov/title 24 to familiarize the design team with these important changes which will affect non-residential projects.  Even though we don’t document energy compliance, the following are some highlights of interest to designers from a summary of changes compiled by Mazi Shirakh, P.E.:

  • Revisions and clarification to Sections 130-134, Mandatory requirements for Lighting Systems and Equipment related to Luminaire Power determination, sign lighting controls, and other clarifications.
  • Updates for compliance to require side-lighting (§131) and day-lit areas near windows, change definition of day-lit area and requirements for daylighting controls.  Update skylight requirements to include smaller buildings (8,000 sf vs. 25,000 sf), buildings with 15 ft ceiling heights (§143(c)).
  • Add requirements for occupant sensors in new indoor areas including small offices, multipurpose rooms less than 1,000 sf, classrooms, and conference rooms(§132(d)).
  • Compliance credit for high efficacy load shedding ballasts to reduce energy use when signaled (§146).
  • Demand response controls to reduce indoor lighting when signaled (§146).
  • Revise the outdoor lighting compliance procedure and update outdoor lighting power densities, require outdoor lighting to meet title 24 standards when alterations replace 30% of fixtures (§147).
  • Revised Cool Roof requirements for low-slope roofs and add prescriptive Cool Roof requirements for steep-sloped roofs (§143).
  • Refinements to additions and alteration requirements for non-residential buildings (§149).
  • Revisions and clarifications to Section 118, Mandatory Requirements for Insulation and Roofing Products including introduction of Solar Reflectance Index (SRI) for cool roof compliance.
  • Revisions and clarifications to section 119, Mandatory Requirements for Lighting Control devices.
  • Changes to Joint Appendix JA4 for wall, roof, and floor assemblies.

We are very interested in your comments and feedback, please email us at feedback@aaidesign.com